Mini Trunking Sizes: A Complete UK Guide for Electricians and Wholesalers
Mini trunking is simple stuff, but getting the size wrong is still a pain. Too small and the lid won't clip on once the cables are in. Too big and it looks clumsy on a skirting board, or doesn't line up with the box.
This guide covers every standard mini trunking size in the Cutterwell range, the difference between standard, self-adhesive and coiled versions, and the fittings and boxes that go with them.

Mini Trunking Sizes at a Glance
All Cutterwell mini trunking is white uPVC. Standard and self-adhesive lengths are supplied in 3m lengths, and coiled versions come in 15m coils (12m for 38 x 16mm).
Size (mm) | Standard | Self-adhesive | Coiled |
16 x 10 | – | – | FM1610W / FMS1610W |
16 x 16 | EM1W | SA1W | FM1W / FMS1W |
25 x 16 | EM2W | SA2W | FM2W / FMS2W |
38 x 16 | EM3W | SA3W | FM3W / FMS3W |
38 x 25 | EM4W | SA4W | – |
38 x 38 | EM5W | SA5W | – |
Ordering Mita mini trunking? The product codes haven't changed, so you can order the same codes you always have.
What Is Mini Trunking?
Mini trunking is a small, surface-mounted uPVC channel with a clip-on lid. It gives you a neat, safe route for a handful of cables where chasing into the wall isn't practical, or isn't worth the mess.
You'll find it on extra sockets and spurs, lighting circuits, alarm and door entry wiring, data and TV cables, and small office or retail jobs. It's used just as much in domestic work as commercial.
Which Mini Trunking Size Do You Need?
Start with the cables. Work out how many will run through it and their size, then pick a profile with some room to spare. A good rule of thumb is to fill no more than 45% of the internal space. That leaves room for heat, makes the lid easier to fit, and gives you space if another cable gets added later.
16 x 10mm
The slimmest option, available in coiled form. Best for single low-voltage cables such as alarm, bell or speaker wire, where you want it as discreet as possible.
16 x 16mm
A small, tidy profile for one or two cables, such as a single power cable or a data run. Matches the standard mini trunking boxes.
25 x 16mm
The most popular size. It has more room than 16 x 16mm without looking bulky, so it suits adding a socket or two. It also fits the standard boxes.
38 x 16mm
Same low height, extra width. Good for a few more cables along a skirting board without the run standing too far off the wall.
38 x 25mm and 38 x 38mm
The largest mini profiles, for heavier runs or where power and data share a route. If you need more space than 38 x 38mm, take a look at midi trunking.

Standard vs Self-Adhesive Mini Trunking
Every size from 16 x 16mm to 38 x 38mm is available in both versions.
Standard (screw-fix): fixed with screws or other suitable fixings. The better choice on uneven, dusty or porous surfaces, and anywhere the run needs to stay put for years.
Self-adhesive: peel and stick, so it's quicker on clean, smooth surfaces like painted walls and skirting boards. Popular for small jobs where speed and a clean finish matter most.
On longer runs or heavier cables, many installers use self-adhesive to position the run and add a few screws to make sure it stays put.
Coiled Mini Trunking
Coiled mini trunking comes in 15m coils (12m for 38 x 16mm), in both standard and self-adhesive versions. It's installed in three steps:
Fix it flat: cut to length and fix in place with suitable fixings or the self-adhesive backing.
Form the sides: fold the sides up and they lock in place with a positive clip action.
Snap on the lid: for a neat finish.
A coil takes up less room in the van and on the shelf, there's less waste from offcuts, and long runs go in faster with fewer joints.

Fittings and Boxes
Every size has its own matching fittings:
Couplings and stop ends
Flat, internal and external angles
Equal and unequal flat tees, side tees and intersection tees
Self-adhesive flanged connectors (16 x 16mm and 25 x 16mm)
For sockets and switches, the MMB surface boxes (1 gang, 2 gang and 2 gang side entry) accept 16 x 16mm and 25 x 16mm mini trunking directly. The TBR and TBU breakaway boxes in 25mm and 32mm depths take mini trunking too, with entry adapters available for 16 x 16mm, 25 x 16mm and 38 x 16mm. All boxes work with both standard and coiled mini trunking.
See the full range of switch and socket boxes.

Standards
Cutterwell mini trunking is manufactured to BS EN 50085-1, BS EN 50085-2-1 and BS 4678 Part 4, and is suitable for installations to BS 7671 (IET Wiring Regulations).
Stocking Mini Trunking at the Counter
Most people asking for mini trunking at the counter want to finish a job today, not wait for an order. A sensible starting point is to hold 16 x 16mm and 25 x 16mm in both standard and self-adhesive, since those two sizes go straight into the standard boxes, along with the matching angles, couplings and stop ends. The larger profiles and coils can then be stocked based on what your customers ask for.
Cutterwell manufactures in Flint, North Wales and supplies exclusively through UK electrical wholesalers, so stock comes direct from a UK site.
Need More Capacity?
If the job needs more cables, compartments to separate power and data, or a run along a whole office, take a look at our perimeter trunking sizes guide.
View the Cutterwell Mini Trunking Range
Every size in this guide, plus the fittings and boxes, is available through the Cutterwell trade portal. Full specs and product codes are in the Buyers Guide.
Not stocking Cutterwell yet? Open a trade account and order through the portal.


Comments