top of page

Mini Trunking Sizes: A Complete UK Guide for Electricians and Wholesalers

Matt Neale
5 days ago
4 min read

Mini trunking is simple stuff, but getting the size wrong is still a pain. Too small and the lid won't clip on once the cables are in. Too big and it looks clumsy on a skirting board, or doesn't line up with the box.


This guide covers every standard mini trunking size in the Cutterwell range, the difference between standard, self-adhesive and coiled versions, and the fittings and boxes that go with them.



Mini Trunking Sizes at a Glance

All Cutterwell mini trunking is white uPVC. Standard and self-adhesive lengths are supplied in 3m lengths, and coiled versions come in 15m coils (12m for 38 x 16mm).

Size (mm) 

Standard 

Self-adhesive 

Coiled 

16 x 10 

– 

– 

FM1610W / FMS1610W 

16 x 16 

EM1W 

SA1W 

FM1W / FMS1W 

25 x 16 

EM2W 

SA2W 

FM2W / FMS2W 

38 x 16 

EM3W 

SA3W 

FM3W / FMS3W 

38 x 25 

EM4W 

SA4W 

– 

38 x 38 

EM5W 

SA5W 

– 


Ordering Mita mini trunking? The product codes haven't changed, so you can order the same codes you always have.


What Is Mini Trunking?

Mini trunking is a small, surface-mounted uPVC channel with a clip-on lid. It gives you a neat, safe route for a handful of cables where chasing into the wall isn't practical, or isn't worth the mess.


You'll find it on extra sockets and spurs, lighting circuits, alarm and door entry wiring, data and TV cables, and small office or retail jobs. It's used just as much in domestic work as commercial.


Which Mini Trunking Size Do You Need?

Start with the cables. Work out how many will run through it and their size, then pick a profile with some room to spare. A good rule of thumb is to fill no more than 45% of the internal space. That leaves room for heat, makes the lid easier to fit, and gives you space if another cable gets added later.


16 x 10mm

The slimmest option, available in coiled form. Best for single low-voltage cables such as alarm, bell or speaker wire, where you want it as discreet as possible.


16 x 16mm

A small, tidy profile for one or two cables, such as a single power cable or a data run. Matches the standard mini trunking boxes.


25 x 16mm

The most popular size. It has more room than 16 x 16mm without looking bulky, so it suits adding a socket or two. It also fits the standard boxes.


38 x 16mm

Same low height, extra width. Good for a few more cables along a skirting board without the run standing too far off the wall.


38 x 25mm and 38 x 38mm

The largest mini profiles, for heavier runs or where power and data share a route. If you need more space than 38 x 38mm, take a look at midi trunking.


Standard vs Self-Adhesive Mini Trunking

Every size from 16 x 16mm to 38 x 38mm is available in both versions.


  • Standard (screw-fix): fixed with screws or other suitable fixings. The better choice on uneven, dusty or porous surfaces, and anywhere the run needs to stay put for years.

  • Self-adhesive: peel and stick, so it's quicker on clean, smooth surfaces like painted walls and skirting boards. Popular for small jobs where speed and a clean finish matter most.


On longer runs or heavier cables, many installers use self-adhesive to position the run and add a few screws to make sure it stays put.


Coiled Mini Trunking

Coiled mini trunking comes in 15m coils (12m for 38 x 16mm), in both standard and self-adhesive versions. It's installed in three steps:


  • Fix it flat: cut to length and fix in place with suitable fixings or the self-adhesive backing.

  • Form the sides: fold the sides up and they lock in place with a positive clip action.

  • Snap on the lid: for a neat finish.


A coil takes up less room in the van and on the shelf, there's less waste from offcuts, and long runs go in faster with fewer joints.

Fittings and Boxes

Every size has its own matching fittings:


  • Couplings and stop ends

  • Flat, internal and external angles

  • Equal and unequal flat tees, side tees and intersection tees

  • Self-adhesive flanged connectors (16 x 16mm and 25 x 16mm)


For sockets and switches, the MMB surface boxes (1 gang, 2 gang and 2 gang side entry) accept 16 x 16mm and 25 x 16mm mini trunking directly. The TBR and TBU breakaway boxes in 25mm and 32mm depths take mini trunking too, with entry adapters available for 16 x 16mm, 25 x 16mm and 38 x 16mm. All boxes work with both standard and coiled mini trunking.


See the full range of switch and socket boxes.

Standards

Cutterwell mini trunking is manufactured to BS EN 50085-1, BS EN 50085-2-1 and BS 4678 Part 4, and is suitable for installations to BS 7671 (IET Wiring Regulations).


Stocking Mini Trunking at the Counter

Most people asking for mini trunking at the counter want to finish a job today, not wait for an order. A sensible starting point is to hold 16 x 16mm and 25 x 16mm in both standard and self-adhesive, since those two sizes go straight into the standard boxes, along with the matching angles, couplings and stop ends. The larger profiles and coils can then be stocked based on what your customers ask for.


Cutterwell manufactures in Flint, North Wales and supplies exclusively through UK electrical wholesalers, so stock comes direct from a UK site.


Need More Capacity?

If the job needs more cables, compartments to separate power and data, or a run along a whole office, take a look at our perimeter trunking sizes guide.

View the Cutterwell Mini Trunking Range

Every size in this guide, plus the fittings and boxes, is available through the Cutterwell trade portal. Full specs and product codes are in the Buyers Guide.


Not stocking Cutterwell yet? Open a trade account and order through the portal.

Comments